MicroSet Model 2

MicroSet Model 2 adds two unprecedented new functions in a clock timing tool. The Count Mode allows you to count the correct rate of any running clock. The Strike Mode records strike counts for diagnosis of errors. Model 2 will measure watches as fast as 36000.00 Beats Per Hour and display Atmos rates to the full resolution of 30 seconds to six decimal places.
Price: $275


Specifications

  • 16 character LCD display
  • 5 button keypad
  • Level control with on/off switch
  • Acoustic pickup for tick sounds, suitable for clocks and watches
  • Optical detector to monitor pendulum swings rather than tick sounds
    (easily measures Atmos and anniversary clocks)
  • Measure beat times from 36.00 BPH ro 36000.00 BPH
  • Resolves beat times to millionths of a second or hundredths of a Beat Per Hour
  • Calibrated to 1 or 2 parts per million at room temperature
    (calibration is under software control and can be recalibrated in the field)
  • Built-in beat amplifier (optional)
  • Computer interface (optional)
  • 8K data buffer for Data Capture (optional)
  • Audible beep tone to signal when long samples have been completed
  • Internal 9 volt battery and 110 volt AC adaptor included
  • Nonvolatile memory for parameter storage
  • Small size (3.5" x 5.5" x 2")
  • Clock train data book included
  • 2 year warranty
  • Large assortment of accessories including alternate optical and watch sensors and precision interface tools.

Functions

  • Time Mode measures the beat time of clock and watches
    (Average 1 to 254 ticks, default value for beat count can be programmed)
  • Display results in Seconds Per Beat or Beats Per Hour
  • Acoustic sensor to measure from the tick sound
  • Automatically disregard extraneous sounds at improper intervals
    (A "blanking window" makes the timer "deaf" between ticks)
  • Optical sensor to measure from the pendulum swing on clocks with pendulums. The optical detector gives more accurate readings and ignores noises like chimes and hourly strike.
  • Special mode for reading Atmos clocks
    (Rate is displayed as 30.000000 Seconds Per Beat)
  • Special mode for finding the rate of unknown movements by measuring the minute hand
  • Beat Error Mode measures the ratio between even and odd ticks to put a clock or watch "in beat".
  • Count Mode determines the correct beat time of any running pendulum clock without train tables or counting teeth.
  • Strike Mode to diagnose inconsistent errors in a strike train.
  • Technical Modes for the experimenter: serve as a tachometer for rotary tools like a lathe or mill, measure the duration of the light and dark phases of an optical sensor, output temperature readings once per second (temperature sensor required), output barometer readings once per second (atmospheric sensor required).

 

MicroSet 2 includes:

  • MicroSet 2 Clock and Watch timer
  • Acoustic sensor
  • Optical sensor
  • 9 volt battery
  • 110 volt AC adaptor
  • The Clockmaker's Beat Book
  • Complete Instruction book

 

MicroSet 2 optional features: